 "id": "france-fere-champenoise-pdl",
 "country": "France",
 "language": "French",
 "convention": "IEC (French NF C 13-100 style)",
 "text_layer": true,
 "quality": "clean CAD export, A3",
 "buyer": "Energie du Partage 8 / Green Energy 3000 (wind farm developer); published in the Préfecture de la Marne public inquiry, 2021",
 "project": "Parc éolien de Fère-Champenoise, delivery substation PDL 1 (Plan 26, nr 5111-E-7026, 04.05.2020); not a tender",
 "drawing": "Plan_26_Schema_unifilaire_A3.pdf, page 1",
 "read_by": "Mavlon, read from the drawing with AI help before any run, November 2026",
 "checks": [
  [
   "Cell count",
   "5 cells in delivery substation PDL 1"
  ],
  [
   "Cell 1",
   "Arrivée Enedis (utility incoming), from the HTA cable from the source substation"
  ],
  [
   "Cell 2",
   "TP mesure Enedis (utility metering VTs), fuses HPCFNwP6 6.3 A"
  ],
  [
   "Cell 3",
   "Disjoncteur protection générale (main circuit breaker), motor-operated, protection C13-100"
  ],
  [
   "Cell 4",
   "Départ transfo aux (auxiliary transformer feeder), fuses HPCFNwP6 6.3 A"
  ],
  [
   "Cell 5",
   "Arrivée éoliennes (wind turbine incoming)"
  ],
  [
   "Busbar",
   "630 A"
  ],
  [
   "Metering VTs",
   "20 kV/√3 to 100 V/√3, 15 VA cl. 0.5, metering and protection windings"
  ],
  [
   "Protection CTs",
   "600/1 A, 5 VA, cl 10P30"
  ],
  [
   "Metering CTs",
   "600/5 A, 7.5 VA, cl 0.2s"
  ],
  [
   "Second CT set",
   "2 x CT 600/5 A 15 VA cl 0.25 (supervision and spare)"
  ],
  [
   "Relays",
   "protection PWH2 and protection GTE type H2, MIA trip"
  ],
  [
   "Auxiliary transformer",
   "20 kVA/230 V, 5 kVA"
  ],
  [
   "Utility meter",
   "Compteur Enedis P+ Q+, P- Q-"
  ],
  [
   "Key interlocks",
   "key legend (clé absente, libre, prisonnière); key 023 on the main breaker; SE and XE keys on cells and turbines"
  ],
  [
   "Turbines",
   "4 x 3.3 MW (Eolienne F1 to F4), total 13.2 MW"
  ],
  [
   "Turbine cables",
   "240 mm² aluminium: 1075 m, 974 m, 1040 m and 62 m"
  ],
  [
   "Other",
   "supervision machine (voltage and current), coffret D.E.I.E, Enedis service limit marked"
  ]
 ]
}